filename: tfs 80h.doc version 1.3 25.10.2006 vi telefilter filter specification tfs 80h 1/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m measurement condition ambient temperature: 23 c input pow er level: 0 dbm terminating impedance: * input: 400 ? || -36 pf output: 400 ? || -43 pf ch aracteristics remark: the reference lev e l for the relativ e attenuation a rel of the tfs 80h is the mini mum of the pass band attenuation a min . the minimum of the pass band attenuation a min is defined as the insertion loss a e . the nominal frequency f n is fix ed at 80,46. the v a lues for relativ e attenuation are guaranteed at ambient temperature. the frequency shift of the filter ov er temperature defined by the temperature coe fficient of frequency tc f is not included in the production tolerance scheme. d a t a ty p. v a lue tolerance / limit insertion loss a e 1 0 d b m a x . 1 6 , 8 d b (reference level) nominal frequency f n - 8 0 , 4 6 m h z pass band p b - f n 1,84 mhz pass band ripple p - p 0 , 4 d b m a x . 1 , 5 d b bandw idth 1,5 db 4,2 mhz 3 db 4,6 mhz 15 db 5,9 mhz max. 6,0 mhz 30 db 6,5 mhz max. 6,6 mhz mean relativ e attenuation a rel 8 6 , 4 7 m h z . . . 9 1 , 5 3 mhz 5 8 d b m i n . 4 6 , 0 d b relativ e attenuation a rel 7 8 , 6 2 m h z . . . 8 2 , 3 0 mhz 0 , 8 d b m a x . 1 , 5 d b 5 5 , 0 0 m h z . . . 6 7 , 0 0 mhz 5 2 d b m i n . 4 4 , 0 d b 6 7 , 0 0 m h z . . . 7 5 , 9 9 mhz 3 5 d b m i n . 3 4 , 0 d b 8 5 , 2 1 m h z . . . 8 6 , 4 7 mhz 4 2 d b m i n . 3 7 , 0 d b 8 6 , 4 7 m h z . . . 9 1 , 5 3 mhz 4 2 d b m i n . 4 0 , 0 d b 9 1 , 5 3 m h z . . . 9 5 , 2 1 mhz 5 5 d b m i n . 4 4 , 0 d b 9 5 , 2 1 m h z . . . 1 0 5 , 0 0 mhz 6 0 d b m i n . 4 5 , 0 d b group delay ripple in pb p - p 9 5 n s - input pow er lev e l - max . 1 0 d b m permissible dc v o ltage - m a x . 0 v operating temperature range otr - -40 c ... + 85 c storage temperature range - -40 c ... + 85 c temperature coefficient of frequency t c f ** -22 ppm/k - *) the terminating impedances depend on paras itics and q-v a lues of matching element s and the board used, and are to be understo od as reference v a lues only . should there be additional ques tions do not hesitate to ask for an applic ation note or contac t our design team. **) ? f c (hz) = tc f (ppm/k) x (t - t o ) x f to (mhz). ge ne ra te d: ch ecked / a p p r o v ed : vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 80h.doc version 1.3 25.10.2006 vi telefilter filter specification tfs 80h 2/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m f ilter ch aracteristic 62. 5 66. 1 69. 7 73 . 3 76. 9 80. 5 84. 1 87 . 7 91. 3 94. 9 98. 5 -6 0 -5 4 -4 8 -4 2 -3 6 -3 0 -2 4 -1 8 -1 2 -6 0 f r eq u e n cy i n m h z m a g n it u d e in d b 77. 5 78. 1 78. 7 79. 3 79. 9 80. 5 81 . 1 81 . 7 82. 3 82. 9 83. 5 -1 0 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 f r e que nc y i n m h z m a g n it u d e in d b cons truc tion a nd pin c onne c t ion date code: y ear + w eek u 2006 v 2007 w 2008 ... 1 ground 2 ground 3 ground 4 output 5 output 6 ground 7 ground 8 ground 9 input 10 input (all dimensions in mm) d a te c o d e s 80h u43 200 oh m t est circu i t vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 80h.doc version 1.3 25.10.2006 vi telefilter filter specification tfs 80h 3/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m stability characteristics after the follow i ng tests the filter shall meet the w hole specification: 1. shock: 500g, 1 ms, half sine w a ve, 3 shocks each plane; din iec 68 t2 - 27 2. vibration: 10 hz to 500 hz, 0,35 mm or 5 g respecti vely , 1 octave per min, 10 cy cles per plan, 3 plans; din iec 68 t2 - 6 3. change of temperature: -55 c to 125c / 30 min. each / 10 cy cles din iec 68 part 2 ? 14 test n 4. resistance to solder heat (reflow ): reflow possible: tw ice max.; for temperature conditions refer to the attac hed "air reflow temperature conditions" on page 4; this filter is rohs compliant (2002/95/eg, 2005/618/eg) packin g tape & reel: iec 286 ? 3, w i th exception of value for n and minimum bending radius; tape ty pe ii, embossed carrier tape w i th top cover tape on the upper side; max. pieces of filters per reel: 3000 reel of empty components at start: min. 300 mm reel of empty components at start including leader: min. 500 mm trailer: min. 300 mm g do w ct f e g d1 p2 p1 po bo ao p u l l o ff d i r e c t i o n pi n m a r k e r ty p da t e c o d e ko t tape (al l di mensi ons i n mm) w : 16,00 0,3 po : 4,00 0,1 do : 1,50 +0,1/-0 e : 1,75 0,1 f : 7,50 0,1 g(min) : 0,60 p2 : 2,00 0,1 p1 : 8,00 0,1 d1(min) : 1,50 a o : 5,50 0,1 bo : 7,50 0,1 ct : 13,5 0,1 a c n w 1 w 2 r eel (all d i men s io n s in mm) a : 330 w 1 : 16,4 +2/-0 w 2 (max ) : 22,4 n(min) : 50 c : 13,0 +0,5/-0,2 the minimum bending radius is 45 mm. vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 80h.doc version 1.3 25.10.2006 vi telefilter filter specification tfs 80h 4/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m a i r re flow te mpe r a t ure c onditions conditions exposure average ramp-up rate (30c to 217c) less than 3c/second > 100c betw een 300 and 600 seconds > 150c betw een 240 and 500 seconds > 217c betw een 30 and 150 seconds peak temperature max. 260c time w i thin 5c of actual peak temperature betw een 10 and 30 seconds cool-dow n rate (peak to 50c) less than 6c/second time from 30c to peak temperature no greater than 300 seconds chip-mount air reflow profile temperature / c max. 260c 217c time / s max. 300 s 10 ... 30 s 30 ... 150 s vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 80h.doc version 1.3 25.10.2006 vi telefilter filter specification tfs 80h 5/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m history version reason of changes name date 1.0 - generation of development s pecification strehl 14.06.2005 1.1 - created filter specification chilla 17.05.2006 - added terminating impedances - added ty pical values - added filter characteristic - changed constructi on and pin connection - added test circuit 1.2 - changed remark chilla 16.06.2006 - added temperature coefficient of frequency 1.3 - changed terminating impedances chilla 25.10.2006 - changed construction and pin connection - changed test circuit vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
|